SELECT ZONE FUNCTIONALITY
Follow these steps to select how a zone will function:
1 – Go to the Main Menu, Settings, (A) and Zones (B) to view the Zone Settings screen (C).*
2 – In this example we will change the function of Zone A to Status Pro. Go to this field (D) to view the Function screen (E).
3 – Scroll the list of functions until Status Pro appears between the arrows (F).
4 – Cancel your selection (I), or save your selection (H).
Follow the same steps to change the functions of zones B and C.
AVAILABLE FUNCTIONS
One of the following three functions can be assigned to a zone:
- Normal
- Status Pro
- Water Temperature
Normal displays solid colors or color patterns that are controllable from the CHROMAZON3 screen (G).
Status Pro displays the spa status as one of the following colors of light.
- Green: spa pack is operational. There are no messages, faults or error codes.
- Blue: spa pack is operational. There is a reminder and/or information message, and there is no fault or error codes.
- Red: there are warning messages or faults present.
- Red (flashing): there are severe warning messages or faults present.
Water Temperature displays the temperature as one of the following colors of light.
- Red: above 108° F (42.2° C).
- Red (flashing): temperature unknown because of a system error or temperature sensor error.
- Orange: between 2° (1° C) above the Set Temperature and 107° F (41.6° C).
- Green: within +/- 2° F (+/- 1° C) of the set temperature.
- Blue: between 46° F (7.7° C) and 2° (1° C) F below the Set Temperature.
- White: less than 45° F (7.2° C).
- Purple: temperature unknown because the water has not been cycled.